Cassese Mach 1, 4, V-Force

FAQ's

Mach 1, 4, V-Force faults & remedies

Gaps at bottom of joined moulding

0 1
  • Ensure the top of the wedge distributor block is level with the bed of the table

Wedges not fully penetrating the moulding

0 2
  • Top clamp pad set too high above the moulding
  • Too soft a clamp pad fitted
  • Wedges upside down
  • Worn wedge distributor block
  • Cartridge spring not attached to the upper mounting holes (cs88 cs89 only)

Wedges getting jammed in the wedge block

0 3

No wedges being fired

0 4
  • Worn cartridge spring
  • Hammer ball catch damaged
  • Cartridge slider broken or needs lubricating
  • Clean the wedge distributor block

When stacking wedges only the first wedge is fired

0 5

Weak joints

0 6
  • Split / damaged clamp pad
  • Poorly positioned wedges